Switch Selectable AC Power for the most
demanding applications
-
Programmable AC test power, 45 to 5000 Hz
-
Power line susceptibility tests: spike, sag, surge
-
Flexible, expandable lab power
-
Precision frequency conversion
-
High reliability UPS
Precision Performance
Design Excellence
Unmatched Flexibility
If you are unwilling to compromise your power quality and reliability, consider
the power source that has proven itself in thousands of demanding applications
- Pacific G-Series.
The simple design concepts used in Pacific’s G-Series equipment have resulted in
continuous application expansion since product inception. Exceptional
reliability and serviceability are a hallmark of G-Series equipment and have
placed G-Series in the most demanding applications for AC Power in the world.
The Controller provides very sophisticated BUS programmable transient
simulations for a wide range of applications.
Power modules provide output frequencies up to 2,000 Hz (5,000Hz optional).
Modules have excellent peak current capability and are short circuit protected
with auto recovery.
Power modules utilize linear power amplifier technology to provide high quality
power and microsecond response to controller stimulus and load power demand.
Output autotransformers provide a broad range of output power forms with
exceptionally high performance for faithful transient simulation.
Power modules operate in single or three phase mode as driven by the controller.
Power modules contain redundant output devices which are electronically
disconnected from system output if failed. Identification of suspect module is
made through service lamps and diagnostic meter on each power module. Power
modules themselves are redundant and can be replaced on-line without shutting
down output power.
G-Series Systems may vary in power from 18 to 90 kVA.
Universal, wide range input magnetics include tap options for common power forms
found throughout the world.
System Configuration
G-Series Systems are readily configurable as frequency converters, line
conditioners, programmable test systems, and uninterruptible power systems.
The basic building block of a G-Series AC Power System is the mainframe. The
mainframe consists of the cabinet and AC to DC power supply. Up to five
mainframes may be paralleled to increase system output power up to 90 kVA.
Each Pacific power source is burned in and meticulously tested before it can
leave the Pacific factory. With close attention to detail, handcrafted
workmanship comes through with every system delivered.
Due to its modular design, failed device disconnect circuitry, and on-line
module replacement, Pacific G-Series Systems are unmatched in reliability and
ease of service.
Model Number Information
Standard Models are complete systems ready for use, including cabinets,
oscillators, input circuit breakers and output contactors. Use model
designations below to design the system that is right for your application.
Model Number Information Table
Control and Power Option
301-F Universal Control Module (Manual)
-
Provides for selection of three different control options:
-
Internal fixed frequencies of 50, 60, and 400 Hz.
-
External signal generator.
-
Input from the SCU/UPC 32 Programmable Controller from 45 to 5000 Hz.
-
Provides for selection of the output power form:
-
Single phase operation or;
-
Three phase operation
-
Provides control of the mainframe output contactor to turn power on and off.
SCU/UPC32 Programmable Controller
-
Provides total control of the output signal from either the front panel keypad
or from a remote computer via the IEEE or RS-232 (optional) BUS. Programmable
parameters include:
-
Frequency
-
Frequency transients
-
Phase angle separation
-
Voltage amplitude
-
Voltage amplitude transients
-
Transient phase (any combination of phases)
-
Transient starting phase angle
-
Waveform generation
-
Requires universal control module
-
Compatibility with UPC Studio graphical user interface
Power Modules (Standard)
120-GR: Enhanced power modules for applications requiring motor starting, high
short circuit current, frequencies from 45 to 2,000Hz (5,000Hz Optional) and
fast transient and harmonic reproduction.
Output Magnetics
-
Standard internally mounted output autoformers provide many popular output
voltage options. See partial listing under System Block Diagram
-
Other special magnetics options are available.
Special Features Available with the SCU/UPC 32 Programmable
Controller
Continuous Self Calibration
Provides for exceptional accuracy of the AC output Voltage. When enabled,
accuracy improves to ±0.03% referenced to the power source internal voltmeter.
Programmable Dynamic Output Impedance (optional)
Programmable Output Impedance provides dynamic control over the output
impedance of the AC Power Source. Using the output current term as conditioned
feedback signal to the output voltage circuits, positive or negative impedance
may be programmed. This control simulates the effects of or compensates for
high peak current, distribution, or transformer losses of up to ±10% of the
output voltage.
This feature creates positive, negative, or zero output impedance (Zo).
-
Compensates for line distribution or transformer losses.
-
Simulates a soft power line for product testing. Compensation range is ±10% of
the output voltage.
Waveform Library
Up to 99 different waveforms may be stored in the waveform library for
execution as part of a steady state test program or for substitution in any
output phase as part of a transient test program. Memory location #1 is a
non-editable high resolution sine wave. Locations 2-16 are editable and may be
substituted in any output phase. Locations 17-32 are factory stored, non
editable waveforms that may be copied to 2-16 for edit and execution.
Waveform Edit
Provides the ability to modify a stored waveform by specifying the waveform
amplitude desired at each specific phase angle. This method can quickly create
spikes, dropouts, notches and other sub-cycle wave conditions. The resulting
modified waveform can be stored for execution.
Waveform Analysis (optional)
Provides both a graphic and numeric display of the harmonic structure of a
voltage or current waveform. The waveform is sampled at 512 samples per cycle
using a 12 bit A/D converter. The resulting high fidelity waveform is analyzed
for its harmonic structure up through the 51st harmonic. Data presented
includes the magnitude of each harmonic in %, the total harmonic distortion,
and the odd and even harmonic distortion in %. Displays Vrms, Irms, Ipk, Power,
VA and PF.
Waveform Synthesis (optional)
Allows you to quickly create virtually any AC Test Waveform that may be
required by building it out of harmonics. The process is as simple as keying in
the harmonic multiple, the amplitude, and the phase angle for each desired
harmonic up through the 51st. If desired, waveforms may also be created in the
time domain by making entries from the front panel or by downloading from a
host PC.
Time Based Transients
Provides the ability to create and execute on command, transients that occur
linearly over a specified time segment to modify output voltage or frequency.
Cycle Based Transients
Create and execute on command, transients that substitute a selected waveform
in the output for 1 to 100 cycles. The waveform being substituted can be
selected and/or modified from the waveform library. Substitution is for an
integer number of cycles, regardless of frequency.
Electrical Specifications
Output Power:
See model listings for appropriate full power ratings.
Output Voltage:
Nominal system voltage is 125 VL-N three phase or single phase. Output voltage
is fully adjustable from 0-125 VL-N. Three phase forms are configured as WYE
and are capable of being loaded either DELTA or WYE.
Alternate Output Voltage:
For output forms other than the nominal 125 VL-N refer to System Block Diagram.
Output Frequency:
Standard with SCU/UPC 32 Programmable: 45-2000 Hz (45-5000 Hz is an option).
Output Current:
See model listings. Peak currents listed are available at the crest of the
voltage sinewave for driving inverter or power supply loads without distortion
or limiting.
Load Power Factor:
Output will drive loads of any power factor leading or lagging.
Load Balance Restriction:
None - all performance specifications apply with any amount of load imbalance.
Load Transient Response:
120-GR, 10 microseconds maximum. Applies to a 100% step change in load, any
phase, or any combination of phases.
1 Phase/3 Phase Operation:
A manual switch allows conversion from 1 phase power forms to 3 phase power
forms, instantly. 3 phase systems may be loaded either as WYE or DELTA.
Input Power Forms:
The G-Series power source is capable of operating from any of the listed input
power forms:
-
Form A: 240 VAC, 3 DELTA, 47-63Hz.
-
Form C: 120/208 VAC, 3 WYE, 47-63 Hz.
-
Form D: 460 VAC, 3 DELTA,
-
3 Ungrounded WYE, 47-63 Hz.
-
Other power forms are available; consult factory.
Failure Isolation System:
Any failed output device, multiple devices or power module is electronically
disconnected from system output. Failure location is identified by service
lamps and diagnostic meter on each power module. Service can be provided when
convenient by replacing power modules.
Power modules can be replaced WITHOUT system shutdown and without disturbances
to system operation.
UPS Option
When performance, maintenance and logistics cannot be compromised choose Pacific
Power Source Systems.
Pacific’s UG-Series Uninterruptible Power Source (UPS) Systems are configured
from standard G-Series AC Sources and UG-18 Battery Support Cabinets. The UG-18
Battery Support Cabinet is a complete battery back-up system that supports any
of the G-Series AC Power Source Systems (6,12, or 18 kVA). One UG-18 cabinet is
provided with each G-Series mainframe offering paralleled systems up to 90 kVA.
Mechanical Specifications
Dimensions (390-G):
A. Height: 50", w/caster base 78"
B. Height: 50.5", w/forklift base 78.5"
C. Width: 23"
D. Depth: 34.5"
Weight: 1,000 Lbs.
Air Flow: 2,000 CFM
Each G-Series mainframe is provided on a caster base with leveling feet for ease
of installation.
Forklift or shock mount base is optionally available. Consult the factory for
details.
Pacific designs and manufactures a broad range of AC Power Sources and
Analyzers. Models range from 500 VA to 625 kVA. Applications include frequency
conversion, AC Test Power, IEC Conformance Testing, and Uninterruptible AC
Power Sources.
Call for Technical and Application Assistance
Pacific’s technical people are committed to assist you. As a technically
oriented company, we design, manufacture and service leading edge AC Test Power
equipment. We understand your requirement for strong applications support and
we provide it.
Product Brochure and Application Notes
To receive a PDF brochure and/or application notes for this product, please
contact us and check the boxes of the specific product(s) that you are
interested in or login in to the PPS Member area and download the files.
Specifications are subject to change without notice.
|